Platinized titanium anode plate with welded connection tab
Platinum-on-Titanium Electrodes · Made in Foshan, China

Platinized Titanium Anodes Engineered Around Your Electrolyte and Drawing

ARY Titanium produces platinum coated titanium electrodes as plates, meshes, rods, tubes and welded assemblies. As a titanium electrode manufacturer, we start from your electrolyte, current load and equipment drawing, so the coated area, connection and geometry fit your cell before the first sample ships.

Electrolyte Current Load Platinum Requirement Geometry

Send us your drawing and operating window — an engineer replies with a coating and geometry proposal.

Material Logic

Why Platinum on a Titanium Substrate

A platinized titanium anode splits the job in two: titanium carries the shape and the current, a thin platinum surface carries the reaction. Understanding that balance helps you specify only what your process needs, instead of paying for platinum where it does no work.

Titanium plates, meshes, rods and tubes used as electrode substrates Structure Side

Titanium Substrate Function

Grade 1 or Grade 2 titanium gives the electrode its form, stiffness and current path. Because titanium passivates where it is not coated, exposed frames and supports stay stable in many electrolytes.

  • Plate, mesh, rod, tube or welded frame chosen to suit your cell
  • Lower weight than solid precious-metal parts of the same size
Balanced by Your Project Conditions

Electrical Connection & Uncoated Zone

Tabs, stems and clamp areas are usually left uncoated. Defining them on the drawing keeps contact resistance predictable and avoids wasting platinum on areas that never see electrolyte.

Electrolyte & Reaction Requirement

The bath chemistry, intended reaction, temperature and current density decide whether platinum is the right surface. We review these first, so the recommendation is based on your conditions, not a generic ranking.

Platinum coated active surface on a titanium electrode with mounting bracket Reaction Side

Platinum Surface Function

The platinum layer is where the electrochemical reaction takes place. Applied only to the active zone, it delivers the surface you need while keeping precious-metal content tied to the real working area.

  • Coated area and edge transition defined on your drawing
  • Thickness or loading matched to your process requirement

We explain construction and selection logic only. Whether platinum, MMO or another surface suits your line is confirmed after reviewing your operating data.

Not sure platinum is the right surface for your bath? Share your conditions and get an honest recommendation.

Ask an Electrode Engineer
Product Cross-Section

Inside a Platinum Coated Titanium Anode

Every platinized titanium electrode we build is documented layer by layer. Knowing exactly which zone is coated, which is bare titanium and where current enters lets your team inspect parts on arrival and reorder the same electrolysis electrode years later.

Exploded view of platinized titanium electrode showing coated mesh, substrate and connection bracket 1Platinum Active Surface 2Prepared Titanium Substrate 3Edge Transition 4Uncoated Connection Zone
Material Inspection Record · Platinized Ti AnodePer Approved Drawing
Product Role

Anode surface for electroplating, electrowinning, special electrolysis and lab cells, sized to your current path.

Titanium Substrate

Commercially pure titanium plate, mesh, rod or tube, cut and formed before coating so the geometry is final.

Surface Preparation

Degreasing, blasting and etching create a clean, keyed surface that supports platinum adhesion.

Platinum Layer

Applied to the active zone only, so precious metal follows the working area instead of the whole part.

Active vs. Inactive Zone

Coated and masked areas are marked on the drawing, giving a clear acceptance reference for incoming inspection.

Connection Zone

Welded tabs, studs or threaded stems kept bare for reliable clamping and stable contact resistance.

Coating Thickness or Loading

Confirmed according to your project requirement and recorded on the approved drawing — we do not quote a generic fixed value, because the right figure depends on your electrolyte, current density and service expectation.

Want a cross-section record like this for your own part? Send the drawing and we will mark every zone for review.

Submit Your Drawing
Electrolyte Compatibility Review

Six Checks Before We Recommend a Platinized Anode

A platinum surface performs well only inside the right operating window. Our engineers review six conditions around your sample before quoting, so you avoid ordering electrodes that look right on paper but fail in your bath.

Electrolyte Composition

Acids, salts, chloride or fluoride content and concentration tell us whether platinum on titanium is a stable choice.

Anodic or Cathodic Role

Knowing whether the part works as anode, cathode or with polarity reversal changes the coating and connection design.

pH and Temperature

Operating pH and bath temperature define the service window, helping us set realistic expectations for lifetime.

Platinized titanium mesh electrode sample mounted on a laboratory stand for electrolyte review
Your Electrode Sample
Under Review

Current Density & Duty Cycle

Continuous, intermittent or pulse operation affects coating wear, so we size the active area to your real load.

Additives & Impurities

Organic additives, metal ions and contaminants can shorten electrode life; flagging them early protects your investment.

Cleaning & Maintenance

Your cleaning method and frequency guide our handling advice, so routine maintenance does not damage the platinum surface.

Send these six data points and receive a written compatibility review within your quotation.

Request an Electrolyte Review
Specification Drawing

Six Annotations That Define Your Platinized Electrode

Most quoting delays come from drawings that show dimensions but not coating boundaries. We mark six points on every platinum coated titanium electrode drawing, giving purchasing, engineering and incoming inspection one shared reference.

Engineering drawing of a titanium mesh electrode next to the finished coated part 123 456
1

Coated Area

The exact zone that receives platinum, so you pay for active surface only where the reaction runs.

2

Uncoated or Masked Area

Frames, supports and clamp zones left as bare titanium, keeping cost and contact behaviour under control.

3

Edge & Transition Requirement

How coating ends at edges and holes, reducing the risk of lifting or uneven wear at boundaries.

4

Substrate Form & Dimensions

Plate, mesh or tube size, thickness and tolerances, so the electrode drops straight into your existing cell.

5

Tab Welding & Electrical Contact

Tab position, weld type and contact face, helping your busbar connection run cool and consistent.

6

Drawing Revision & Inspection Points

Revision number and check points recorded, so every repeat order matches the part you approved.

Have a drawing without coating boundaries? We will mark these six points with you during quotation review.

Get Your Drawing Annotated
Electrode Geometry

Six Titanium Forms, Each Solving a Different Cell Problem

The shape of a platinized titanium anode controls how electrolyte flows, how current spreads and how the part is mounted. We cut, form and weld every substrate in-house, so the geometry is matched to your tank instead of forcing your tank to fit a stock part.

Flat platinized titanium plate anodeFORM 01 · PLATE

Solid Plate Anode

A continuous surface gives even current distribution facing flat parts, helping keep deposit thickness uniform.

Fluid Access

Flow along faces

Connection

Welded top tab

Woven style titanium mesh electrode with platinum coatingFORM 02 · MESH

Mesh Anode

Open area lets gas escape and electrolyte circulate, which helps reduce voltage rise from trapped bubbles.

Fluid Access

Through-flow

Connection

Frame or bar weld

Expanded titanium mesh anode with welded conductor barFORM 03 · EXPANDED MESH

Expanded Mesh Anode

Diamond openings add effective surface without adding weight, giving more working area per kilogram of titanium.

Active Area

High per weight

Rigidity

Stiffener options

Titanium rods, mesh and plate electrode blanks laid out for coatingFORM 04 · ROD

Rod Anode

A compact profile fits narrow cells, inner bores and lab fixtures where a plate cannot reach the working zone.

Mounting

Threaded or clamped

Connection

Bare top stem

Titanium tube and plate electrode substrates for platinum coatingFORM 05 · TUBE

Tube Anode

Coating inside or outside a tube suits flow-through and concentric cells, so electrolyte passes the active surface evenly.

Fluid Access

Flow-through

Coated Face

ID, OD or both

Custom welded titanium electrode stack assemblyFORM 06 · ASSEMBLY

Custom Welded Assembly

Multiple plates or meshes joined with frames and conductors arrive ready to install, cutting assembly time on your side.

Support

Spacers & frames

Connection

Busbar ready

The final form, opening size and connection are always set by your equipment drawing and operating conditions — the six forms above are starting points, not fixed catalogue models.

Tell us your cell size and mounting method, and we will suggest the form that fits with the least modification.

Match a Geometry to My Cell
Applications

One Electrochemical Requirement, Six Different Electrode Answers

Platinized titanium anodes are used across very different processes. Each one changes the electrolyte, reaction, electrical load, geometry and validation plan, so we design for your specific line rather than promise one part fits every use.

Your Electrochemical Requirement
Electroplating line with tanks and titanium anode baskets

Electroplating

Insoluble platinized anodes keep anode-to-part distance stable, helping deposits stay consistent between maintenance stops.

ElectrolytePrecious-metal & specialty baths
GeometryPlate or mesh facing parts
ValidationDeposit thickness check
Electroplating electrodes
Electrowinning tank house with cathodes being lifted by crane

Electrowinning & Metal Recovery

Large-format coated meshes recover metal from solution while titanium frames carry high current to every cell.

ElectricalHigh current, long duty
GeometryLarge mesh, busbar hooks
ValidationCell voltage trend
Electrowinning anodes
Stacked electrolytic cell skid for special electrolysis

Special Electrolysis

Organic synthesis and specialty chemical cells use platinum surfaces where the reaction pathway calls for them.

ReactionDefined by your process
GeometryPlates to fit cell stack
ValidationYield & selectivity test
Electrolytic cell electrodes
Water electrolysis unit with electrode modules in blue frame

Hydrogen-Rich Water Devices

Small platinized plates and meshes suit compact water electrolysis modules where space and contact quality matter.

ElectrolyteLow-conductivity water
GeometrySmall plate or mesh
ValidationModule-level test
Water device electrodes
Electrochemical equipment with electrode stack and cabling

Electrochemical Equipment OEM

Equipment builders get repeatable electrodes to drawing, so every machine leaving their line performs the same.

ElectricalPer equipment rating
GeometryDrawing-controlled
ValidationBatch consistency
OEM electrode supply
Laboratory electrochemical test cell with power supply and beaker

Laboratory & Pilot Systems

Low-quantity electrodes for research cells let your team test a concept before committing to production tooling.

ReactionExperimental, varies
GeometrySmall custom parts
ValidationYour lab protocol
Lab-scale electrodes

Suitability for each application is confirmed only after reviewing your electrolyte and operating data.

Describe your process in two lines and we will tell you which electrode configuration to start testing.

Discuss My Application
Project Specification

Your Whole Electrode Project on One Specification Page

Instead of scattered emails, we consolidate electrolyte, platinum requirement, substrate, geometry, connection and purchasing terms into one controlled page. Your engineers and buyers sign off on the same document, and nothing gets lost between sample and repeat order.

DocumentPlatinized Ti Anode · Project Spec
Prepared byARY Engineering
Approved byYour Team
StatusControlled Revision
Engineering drawings and specification documents on an electrode workshop desk

Every repeat order is built from this signed page, so the tenth batch matches the first approved sample.

01

Application & Reaction

Process type and intended reaction, so the surface is chosen for what actually happens in your cell.

PlatingElectrowinningSynthesis
02

Electrolyte & Operating Window

Composition, pH, temperature and current density recorded as the reference for lifetime expectations.

pHTemp.A/dm²
03

Platinum Requirement

Where applicable, coated area and thickness or loading agreed in writing, protecting your budget and performance.

Coated AreaPer Project
04

Titanium Form & Active Area

Substrate grade, form, dimensions and active area fixed, so the electrode fits without on-site rework.

Gr1 / Gr2MeshPlate
05

Mounting, Welding & Connection

Tab, stud or busbar design and weld locations defined, reducing contact heating and installation time.

TabStudBusbar
06

Validation, Quantity & Confidentiality

Sample plan, order quantity, delivery terms and NDA status kept together for a predictable purchase cycle.

SampleMOQNDA

No template needed — send whatever data you have, and we will build the specification page with you.

Start My Project Specification
Surface Diagnostics

Seeing a Change on Your Electrode? Look Closer Before You Replace It

Discoloration, deposits or rising voltage can come from operating conditions, cleaning or connections, not only the coating. We help you check the right data first, so you fix the real cause and avoid replacing electrodes that still have service life left.

Surface Discoloration

Check: bath chemistry changes, temperature log and recent cleaning agents.

Deposits & Scaling

Check: water hardness, impurity ions and the cleaning interval in use.

Scratches & Handling Marks

Check: installation tools, rack contact and handling during maintenance.

Magnified microstructure of an electrode coating surface

Magnified Surface View

Local Surface Damage

Check: current concentration at edges, short-circuit events and spacing.

Connection Heating

Check: clamp torque, contact surface condition and busbar alignment.

Cell Voltage Change

Check: voltage trend versus load, electrolyte conductivity and batch history.

We never judge a failure cause from a photo alone — conclusions are drawn only after operating data and, where needed, part inspection.

Share your photos and operating records, and our engineers will tell you what to check first.

Request a Surface Review
Why ARY Titanium

Manufacturing Evidence You Can Verify, Not Just Claims

ARY Titanium is a titanium electrode manufacturer based in Foshan, Guangdong, China. Cutting, forming, welding, coating, measuring and packing happen under one roof, so you deal with one accountable supplier and get faster answers when your project changes.

Foshan, ChinaFactory & engineering team
19 YearsIndustrial equipment experience
7 Export MarketsAmericas, Europe, Asia, Middle East
One SupplierDesign to export packing

Want to see our process for yourself? Ask for a video factory walkthrough or recent production photos.

Request Factory Evidence
OEM & Long-Term Supply

An OEM Electrode Partner That Works Like Part of Your Team

Equipment builders need more than a part — they need a supplier who protects their design, keeps part numbers straight and ships the same electrode for years. Our OEM desk tracks six workstreams for every program so nothing depends on memory.

ARY engineers and an OEM customer reviewing electrode drawings together
One Program, One Contact

A dedicated engineer follows your part from drawing review to repeat supply, so you never re-explain your project.

Step 1

Engineering Review

Your drawing and process data are checked for manufacturability before quoting, reducing late design changes.

Step 2

Drawing & Platinum Requirement Confirmation

Coated area and platinum requirement confirmed in writing, so cost and performance are agreed upfront.

Step 3

Sample & Pilot Validation

Samples and pilot lots are tested in your equipment before your production schedule depends on them.

Step 4

Inspection & Batch Reference

Each lot carries your part number and batch reference, making field service and audits straightforward.

Step 5

Private Label Packaging & NDA

We sign NDAs and pack under your brand, so your end customers see your name and your design stays protected.

Step 6

Replacement & Repeat Supply

Approved drawings stay on file, so replacement electrodes years later match the original installation.

Building equipment that needs platinized electrodes? Let's set up your OEM program under NDA.

Start an OEM Program
Knowledge Index & FAQ

Frequently Asked Questions About Platinized Titanium Anodes

Straight answers to the questions buyers and engineers ask us most about platinum coated titanium electrodes. Use the index to jump to a topic, and open any question to read the answer.

AWhat is a platinized titanium anode?

It is a titanium electrode with a thin platinum surface on its active area. Titanium provides shape, strength and current path, while platinum provides the reaction surface — giving a platinum working face at a fraction of the metal content of solid platinum.

BHow do I know if platinum suits my electrolyte?

Send the bath composition, pH, temperature, current density and intended reaction. Our engineers review compatibility and tell you plainly whether a platinized titanium anode, MMO or another surface is a better starting point.

AWhat platinum thickness or loading will I receive?

It is confirmed per project based on your electrolyte, current density and service expectations, then written on the approved drawing. We do not quote a generic fixed value, because a figure that ignores your conditions would not protect your budget.

BCan a platinized electrode be used with polarity reversal?

Possibly, depending on reversal frequency, electrolyte and current. Tell us how your system switches polarity, and we will assess it during the compatibility review before recommending a design.

CCan you coat only part of the electrode?

Yes. Coated and masked areas are defined on the drawing. Leaving tabs, frames and clamp zones as bare titanium reduces cost and keeps connection areas clean for reliable contact.

DHow should the electrical connection be designed?

We recommend welded titanium tabs, studs or conductor bars sized for your current, with an uncoated contact face. Share your busbar arrangement and we will propose a connection that limits heating at the joint.

CWhich forms and sizes can you make?

Plates, meshes, expanded meshes, rods, tubes and welded assemblies, cut and formed to your drawing. Size limits depend on form and coating equipment, so send the dimensions and we will confirm feasibility.

EHow should I clean and handle platinized anodes?

Avoid abrasive tools and impact on the coated surface, and use cleaning agents agreed for your bath. We provide handling advice with each project so routine maintenance does not shorten electrode life.

FWhat commonly causes premature electrode problems?

Common contributors include operating outside the agreed window, contaminants in the bath, current concentration at edges, poor clamp contact and mechanical damage during handling. Reviewing operating data usually narrows the cause quickly.

FWhat is the minimum order and sample lead time?

We support sample and small-batch orders for validation. Lead time depends on form, size and coating requirement, and is confirmed in the quotation once your drawing has been reviewed.

Didn't find your question? Ask our engineers directly — technical questions are answered by people who build the electrodes.

Ask a Technical Question