Custom titanium mesh electrode beside its engineering drawing, caliper and CAD model
Drawing-Based OEM Electrodes · Foshan, China

Custom Titanium ElectrodesBuilt to Your Cell, Not a Catalog

As a custom titanium electrode manufacturer with R&D, coating and fabrication under one roof, ARY Titanium turns your drawing, sample or equipment measurements into a coated electrode that fits your cell the first time. You avoid the rework, refitting and early coating failure that come from buying a standard size and adapting it.

Made to your dimensionsHoles, tabs and active area as drawn
Coating by conditionsMatched to electrolyte and current
1–10 piece samplesValidate before you commit volume

Have a drawing, part or measurement ready? Get a manufacturability review before you get a price.

Electrode Canvas · Rev A
270 ±0.5 130 Ø12 tab Active area · MMO coated
Three Ways to Start

Start From What You Already Have: a Drawing, a Sample or Your Equipment

You do not need a finished specification to begin. Each starting point has its own review path, so our engineers ask only for the data that is missing and your project moves to a sample without weeks of back-and-forth emails.

Customer electrode drawing reviewed next to a titanium mesh partRoute 01

Customer Drawing

Your drawing becomes the controlled reference for cutting, forming, welding and coating, so every batch is built to the same revision.

We check on your drawing
  • Revision number, dimensions and tolerances
  • Titanium grade, coating and active area
  • Tabs, studs, holes and connection details
Feasibility comments arrive before quotation, not after the first failed fit.
Engineers measuring an existing titanium electrode sampleRoute 02

Existing Sample

A used or current electrode tells us more than a photo. We measure it, inspect the coating wear and record what must stay the same.

We record from your sample
  • Full dimensions, form and connection layout
  • Wear pattern and failure history in service
  • Features you approve to keep or improve
You receive a measured drawing for approval, so the replacement is traceable from day one.
Technician taking caliper measurements for an electrode fit-upRoute 03

Equipment Measurements

Designing a new cell or retrofitting old equipment? Give us the space and interfaces, and we propose an electrode that fits them.

We need from your equipment
  • Available space, gap and mounting points
  • Busbar, terminal and power supply data
  • Flow path, sealing and service access
A proposed drawing you can check against your cell before any titanium is cut.

Whichever route you choose, the operating conditions decide the coating. Share these five values and we can recommend a coating direction instead of guessing from the shape alone.

Electrolyte & pH Current density Temperature Duty cycle Target service life

Not sure which route fits your project? Tell us what you have and we will tell you what is missing.

Choose My Starting Point
No Fixed Model Number

Your Project Defines the Electrode, Step by Step

A custom titanium anode is not picked from a price list. It is defined by your operating conditions, reaction, form, mounting and validation plan. Building it in this order means the coating suits your chemistry and the part suits your cell, which is what keeps drawing-based titanium electrodes working in the field.

Input 01

Operating Conditions

Electrolyte, pH, current density and temperature set the limits, so the coating is not chosen blind.

Input 02

Target Reaction & Coating Direction

Chlorine evolution, oxygen evolution or metal deposition points to the coating family worth testing.

Input 03

Titanium Form & Active Area

Plate, mesh, rod or tube is chosen for current distribution, gas release and flow in your cell.

Undefined Electrode → Your Specification
Exploded view of a custom titanium electrode with coated mesh and welded tab

Each input narrows the design, so the final part is specified by your project, not adapted from someone else's.

Input 04

Geometry, Mounting & Connections

Tabs, studs, busbars and supports are designed with the electrode, cutting hot spots and fit-up time.

Input 05

Validation & Repeat Supply

Sample tests, inspection points and packaging are agreed early, so reorders match the approved part.

Result

A Custom Electrolysis Electrode on File

One controlled drawing and process record that we build to for every future order.

Missing one of these inputs? Send what you have and our engineers will fill the gaps with you.

Start My Electrode Specification
Six-Axis Specification

Configure the Six Variables That Decide Electrode Performance

Every custom titanium anode we quote is built from the same six axes. Setting them up front gives you a comparable quotation, a clear sample plan and fewer surprises when the electrode goes into your equipment. Try the options below to see how a specification takes shape.

Close-up of a coated titanium electrode plate with welded connection tab
Your draft specification
Application
Water disinfection
Coating
Ru-Ir MMO
Form
Expanded mesh
Tolerance
±0.5 mm
Connection
Welded tab
Delivery
1–10 pc sample

Application & Electrolyte

Sets the chemistry window

Coating Direction

Discussed, then sample-tested

Titanium Form

Controls flow and gas release

Dimensions, Active Area & Tolerance

Decides fit in your cell

Mounting, Welding & Busbars

Where current enters the part

Sample, Inspection & Repeat Supply

Protects every later batch

Send us your six answers, even rough ones, and receive a reviewed specification with a quotation.

Submit My Configuration
Titanium Form Toolbox

Pick the Titanium Form That Suits Your Reaction and Your Cell

Shape changes current distribution, gas release, flow and stiffness. Select a form below to see what we can adjust and what we need you to confirm, so the substrate is chosen for performance rather than habit.

Coated titanium plate electrode with connection tabPlate

Titanium Plate Electrode

A flat, rigid surface gives even current distribution where the electrode gap must stay constant, which keeps cell voltage predictable.

AdjustableLength, width, thickness, holes
Active areaFull face or masked zones
RigidityHigh, suits narrow gaps
Fluid accessLow, add slots if needed
Please confirm: flatness requirement, electrode gap and whether both faces are active.
Woven titanium mesh electrode with conductor rodMesh

Titanium Mesh Electrode

Open mesh lets gas escape and electrolyte pass through, lowering bubble resistance in chlorine and oxygen evolution cells.

AdjustableOpening size, wire, outline
Active areaHigh surface per footprint
RigidityMedium, add edge bars
Fluid accessHigh, through-flow
Please confirm: flow direction, opening size limits and how the mesh is supported.
Expanded titanium diamond mesh anode panelExpanded Mesh

Expanded Titanium Mesh Anode

One-piece expanded sheet with no wire joints, so it carries current evenly and holds its shape better than woven mesh at similar weight.

AdjustableDiamond size, strand, sheet gauge
Active areaHigh with good gas release
RigidityMedium to high
Fluid accessHigh, directional pattern
Please confirm: diamond orientation in the cell and the current feed position.
Cylindrical titanium mesh anode on a rod in a laboratory standRod

Titanium Rod & Rod-Mesh Anode

Rod and rod-mounted mesh anodes fit pipes, tanks and compact reactors where a flat plate cannot, with current fed through one end.

AdjustableDiameter, length, thread
Active areaRod only or mesh sleeve
RigidityHigh along the axis
Fluid access360° exposure
Please confirm: immersion depth, sealing method and thread or fitting standard.
Titanium tube, plate and perforated sheet substrates on a workbenchTube

Titanium Tube Electrode

Tubular electrodes work as both electrode and flow channel, a compact layout for inline disinfection and concentric cells.

AdjustableOD, wall, length, ends
Active areaInside, outside or both
RigidityHigh
Fluid accessDefined annular flow
Please confirm: which surface is coated, concentricity and end connections.
Titanium frame with coated mesh insert and mounting tabsFrame

Framed Mesh Electrode

A titanium frame keeps large mesh panels flat and gives you fixed mounting points, so installation is repeatable across units.

AdjustableFrame section, mesh insert
Active areaInside frame only
RigidityHigh for large panels
Fluid accessHigh through the insert
Please confirm: panel size, mounting hole pattern and frame coating needs.
Close-up of a welded titanium connection on a coated electrodeWelded Assembly

Welded Electrode Assembly

Multiple plates, meshes, conductor bars and tabs joined into one part, so you install a finished assembly rather than loose pieces.

AdjustableLayout, spacing, conductor size
Active areaPer component on drawing
RigidityDesigned per assembly
Fluid accessSet by spacing
Please confirm: current per connection, weld inspection level and assembly tolerances.
Form follows function: we will flag a form that conflicts with your reaction, flow or mounting before you order a sample.

Unsure between plate, mesh or a welded assembly? Send your cell layout and we will recommend a form.

Get a Form Recommendation
Drawing Review Overlay

We Review Your Drawing in Five Layers Before We Quote

Your drawing is checked against manufacturing, electrochemistry, inspection and revision control at the same time. Problems such as an unreachable weld, an oversized active area or a missing tolerance are found on paper, where they cost nothing to fix. Switch the layers to see what each review looks at.

Engineering drawing of a titanium mesh electrode reviewed with caliper and sample
1Dimensions & tolerances
1Hole positions
2Weld access & bending radius
2Busbar & support fit
3Active area vs. current
3Masked & sealing zones
4Flatness check points
5Rev. B · approval block

Customer Drawing Layer

Dimensions, tolerances and hole positions are read as you wrote them, so nothing is reinterpreted in production.

Manufacturing Feasibility

Cutting, forming, welding access and support fit are checked, so the part can be built without hidden extra cost.

Electrochemical Requirement

Active area, current feed and sealing zones are matched to your load, reducing hot spots and uneven coating wear.

Inspection & Packaging

Check points and protective packing are added to the drawing, so you know how each piece will be accepted.

Revision & Approval

Every change gets a revision letter and your sign-off, so the approved part is the one that gets repeated.

Upload your drawing and receive layer-by-layer review comments before any price is fixed.

Request a Drawing Review
Conditions → Coating Direction

Your Operating Data Points to the Right Coating, Not a Generic Model

An MMO titanium anode that lasts in brine can fail quickly in acidic sulfate. We map your electrolyte, reaction, current, temperature and service routine to a coating direction, then confirm it with samples. You pay for the coating your process needs, without over-specifying precious metal loading.

What you tell us

Electrolyte Chemistry

Chloride, sulfate, fluoride or organics, plus pH and concentration.

Intended Reaction

Chlorine evolution, oxygen evolution or metal deposition at the anode.

Electrical Window

Current density, voltage and whether polarity is reversed.

Temperature & Duty Cycle

Bath temperature, hours per day and start-stop frequency.

Cleaning & Service

Acid cleaning, descaling, storage and expected service life.

Coating direction for review
Microscope image of a mixed metal oxide coating surface on titanium
Chloride media · Cl₂ evolution

Ru-Ir MMO Titanium Anode

A common direction for hypochlorite, electrochlorination and pool disinfection, where chlorine output per watt matters.

Brine & seawaterCl₂ efficiencySample tested
Laboratory electrolysis test of a titanium anode in acidic solution
Acidic media · O₂ evolution

Ir-Ta MMO Titanium Anode

Considered for sulfate electrolytes, electrowinning, plating and oxidation duties where oxygen is the main anode reaction.

Sulfuric mediaO₂-evolving dutyLoad-dependent
Platinum coated titanium electrodes under bench testing
Special duty · low contamination

Platinized Titanium Anode

Platinum coated titanium electrodes are reviewed for precious-metal plating, hydrogen water and lab cells needing a clean surface.

Plating bathsHydrogen waterPt per duty
A coating direction is a starting point for discussion. We confirm the final coating and loading with your sample test results, never from a catalog table alone.

Share your electrolyte and current data to receive a coating recommendation you can test.

Get My Coating Recommendation
Application Map

One Engineering Team for Every Electrochemical Application You Build

Each application sits in a different place on reaction type and equipment complexity, which changes the coating, the structure and the validation you need. Find your equipment on the map: we have customized electrodes for each zone, so your project starts from relevant experience instead of a blank page.

Water & Wastewater

Frames and supports sized to flow, so electrodes stay aligned in long service runs.

Hypochlorite & Pool

Gap and active area set for chlorine output, giving you predictable dosing per cell.

Electrodialysis

Coatings checked for polarity reversal, so descaling cycles do not shorten electrode life.

Hydrogen Water

Small, tightly toleranced parts suited to compact devices and high-volume assembly.

Plating & Electrowinning

Conductor and busbar design for high current, limiting voltage loss across large anodes.

R&D & Pilot Cells

Small sample quantities with documented builds, so lab results scale to production.

Building something not on the map? Tell us the reaction and the equipment, and we will review it.

Discuss My Application
Manufacturability Review

Risks Are Flagged on Our Board Before They Reach Your Production Line

Every custom project goes through a structured risk review. Instead of a quotation that hides assumptions, you receive a status for each risk and a short list of what we still need. That saves you a failed sample, a missed launch date or a reorder that no longer matches.

ARY engineering team reviewing electrode drawings for manufacturability

What a review result looks like

Engineering, coating and quality staff review your file together. Each item is marked with a status, and each open item tells you exactly which value or decision closes it. You decide with full information, not after the parts are made.

Blocks quotation Needs your input Confirmed

Missing Operating Data

Blocks quote

Without current density or temperature, any coating offer is a guess that could fail early in service.

We ask for: electrolyte, current density, temperature, duty cycle.

Coating Not Confirmed

Needs input

The drawing says "MMO" but not the reaction. We propose a direction and a sample test to confirm it.

We ask for: target reaction and expected service life.

Geometry or Tolerance Conflict

Needs input

A tight flatness callout on thin mesh may not survive coating heat. We suggest a workable value first.

We ask for: which tolerances are functional and which are nominal.

Welding or Connection Risk

Blocks quote

An undersized tab carrying full cell current overheats. We size the connection to the load you specify.

We ask for: current per electrode and terminal type.

Inspection Requirement Gap

Needs input

If acceptance criteria are not written down, two batches can both "pass" and still differ in your cell.

We ask for: critical dimensions and any reports you require.

Quantity or Schedule Risk

Confirmed

Sample, pilot and series quantities are planned against coating capacity, so dates you receive are realistic.

We ask for: sample date, pilot size and forecast volume.

Want to see where your project stands? Send your file for a manufacturability risk review.

Get My Risk Review
Prototype Sprint Board

From First Data to Approved Electrode on One Visible Board

Custom prototypes stall when nobody knows who owes the next step. We run every project on six stages with a clear input from you, an output from us and a written done condition. You always know where the electrode is and what will move it forward.

Data

01
Engineer collecting customer operating data at a workstation
You provide

Application, electrolyte, current and target life.

ARY delivers

Gap list and coating direction.

Done when

All operating values are agreed in writing.

Drawing

02
CAD model of a titanium electrode on an engineering monitor
You provide

Drawing, sample or cell measurements.

ARY delivers

Production drawing with review notes.

Done when

You sign Rev A for sampling.

Sample

03
Inspector checking a coated titanium mesh sample under a magnifier
You provide

Sample quantity, from 1 to 10 pieces.

ARY delivers

Coated samples with inspection record.

Done when

Samples arrive and pass your fit check.

Test Feedback

04
Titanium electrode sample running in a transparent test cell
You provide

Voltage, output and wear after testing.

ARY delivers

Analysis and any design or coating change.

Open item

Results must cover your real duty cycle.

Pilot

05
Pilot batch of titanium electrode assemblies on the production line
You provide

Pilot quantity and field test sites.

ARY delivers

Small batch built on the series process.

Done when

Batch matches samples in your units.

Approved

06
Signed approval documents for an electrode specification
You provide

Final approval and forecast volume.

ARY delivers

Locked drawing, part number, packing spec.

Done when

Series orders repeat the approved part.

Status updates at every stage change, not only when you ask.
Open items marked so missing information never hides.
Loops allowed: a stage can repeat without restarting the project.

Ready to put your project on the board? Start with the data you have today.

Start My Prototype Sprint
Revision & Change Control

Every Drawing Change Is Traced, So Repeat Orders Match What You Approved

Long-term OEM supply fails quietly when a small change is never recorded. We keep a version tree from first drawing to series production, with the reason and your approval for each step. Your buyers reorder by part number and receive the same electrode as last year.

Initial electrode drawing and calculations on an engineering desk
Initial drawing

Rev A · Sample Release

ReasonFirst manufacturable version of your design.
ApprovalYour engineer signs before sampling.
Quality engineer comparing revised electrode samples with the drawing
Sample revision

Rev B · After Test Feedback

ReasonHole moved 2 mm, tab widened for current.
ApprovalMarked-up changes confirmed by you.
Technician building a pilot electrode to the revised drawing
Pilot revision

Rev C · Pilot Batch

ReasonInspection points and packing added.
ApprovalPilot report accepted by your QA.
Series production batch of identical titanium electrodes
Series version · locked

Rev D · Production Release

ReasonFrozen for repeat supply under your part number.
ApprovalEarlier revisions locked from production.

Drawing Revision

Letter and date on every sheet

Reason for Change

Written cause for each edit

Customer Approval

No release without your sign-off

Inspection Update

Check sheet follows the drawing

Part No. & Packaging

Labels updated with the revision

Superseded Lock

Old versions cannot be built

Moving an existing electrode to a new supplier? We start your version tree from your current drawing.

Set Up Controlled Supply
Inspection Coverage Map

Quality Checks Mapped Directly onto Your Electrode

Inspection is planned against your drawing, not a generic checklist. Six numbered check zones cover material, coating, dimensions, welds, active surface and identification, so the electrodes you receive install without sorting, shimming or rework.

Coordinate measuring machine checking flatness of a titanium electrode plate 1 2 3 4 5 6 Check zones follow your drawing
1

Incoming Material

Titanium grade and thickness checked against the mill certificate before cutting.

Traceable to your order
2

Surface Prep & Coating

Blasting, etching and coating cycles recorded per batch for a consistent coating base.

Batch process record
3

Dimensions & Flatness

Critical dimensions, hole positions and flatness measured to your stated tolerances.

Measured values on request
4

Welding & Connections

Welds, studs and tabs visually checked and tested for secure current transfer.

Prevents hot spots in service
5

Active Area & Surface

Coating coverage, color uniformity and masked zones inspected over the active area.

Uniform current distribution
6

ID & Packaging

Part number, revision and batch marked; packed to protect the coated surface in transit.

Ready for your incoming QC

Tell us which dimensions matter most and we will build your inspection plan around them.

Request an Inspection Plan
OEM Co-Design Room

Your Engineers, Buyers and QA Work Directly With Our Factory Team

ARY Titanium is a titanium electrode manufacturer in Foshan, China, with R&D, coating, fabrication and sales in one company. Your engineering, purchasing and quality staff each get a direct counterpart, so technical answers, prices and inspection data do not pass through a middleman.

Customer and ARY engineers reviewing an electrode design together
~100Employees
3-in-1R&D, production, sales
1–10 pcSample orders
OEM/ODMDrawing-based supply

Engineering Clarification

Your engineer talks to ours about coating, current and fit, so questions close in days, not weeks.

Purchasing & Schedule

Quotes broken down by sample, pilot and series quantities, with dates tied to real capacity.

Quality & Acceptance

Acceptance criteria agreed with your QA before production, so incoming inspection is simple.

NDA & Drawing Protection

We sign your NDA before receiving files and use your drawings only for your orders.

Packaging & Export

Export crates that protect coated surfaces, with documents prepared for your customs.

Repeat Supply

Approved parts reordered by part number and revision, keeping your product consistent.

Titanium electrodes packed in export wooden crates

Custom electrodes delivered to equipment builders in 7 countries

Our export experience means familiar paperwork, packing and lead-time planning for your market.

USA Germany UK India Australia UAE Saudi Arabia

What Equipment Builders Say

"They pointed out a tolerance conflict on our mesh drawing before quoting. The first samples fitted our cell without rework."

Technical Purchasing ManagerWater treatment OEM · Germany

"We sent a worn electrode and our cell dimensions. We got back a measured drawing to approve and a coating suggestion for our brine."

Engineering LeadHypochlorite generator maker · USA

"Small sample quantities let us test two coating options side by side before committing to a pilot batch."

R&D EngineerElectrochemical equipment · Australia

"Repeat orders arrive with the same part number, revision and packing as the approved batch, which keeps our assembly simple."

Supply Chain ManagerElectrodialysis systems · UAE

Want our engineers in your next design review? Send an NDA or your project brief to start.

Book a Technical Discussion
Design Knowledge Base · FAQ

Frequently Asked Questions About Custom Electrode Design

Straight answers to the questions engineers and buyers ask most often when they work with titanium electrode manufacturers. Use them to prepare your project and get a faster, more accurate quotation.

ARY engineer answering a customer question about electrode design

Jump to a topic

Click a topic to open the answer.

01What operating data do you need to design a custom titanium electrode?
At minimum: electrolyte composition and pH, current density, temperature, duty cycle and the reaction you want at the anode. Add the expected service life and any cleaning or polarity reversal. With these values we can recommend a coating direction instead of guessing from the electrode shape.
02How is the coating direction for a custom electrolysis electrode decided?
We start from the reaction. Chloride media with chlorine evolution usually points to a Ru-Ir MMO coating; acidic oxygen-evolving duty points to Ir-Ta MMO; some plating, hydrogen water and lab cells use platinized titanium. The direction is then confirmed with your sample test, because current, temperature and impurities change real-world results.
03How should I prepare a manufacturing drawing?
Include overall dimensions with tolerances, titanium grade and form, the coated active area, hole and tab positions, connection details and a revision number. DWG, DXF, STEP or PDF all work. If you only have a sketch or a sample, we can create the drawing for your approval.
04How do I specify welding and electrical connections?
Tell us the current per electrode, terminal type (tab, stud, busbar or titanium-clad copper) and how the part is mounted. We size the connection for that load and mark weld positions on the drawing, which helps avoid hot spots and early failure at the joint.
05How should we plan samples and validation?
Most projects start with 1–10 sample pieces, tested in your own cell under your duty cycle. Share voltage, output and surface condition after testing; we adjust design or coating if needed, then build a pilot batch on the series process before volume orders.
06How are revisions and repeat orders controlled for titanium mesh anode OEM supply?
Each approved drawing receives a revision letter and your part number. Changes are recorded with a reason and your approval, inspection sheets are updated with them, and superseded revisions are locked so they cannot be produced by mistake.
07What is the minimum order and typical lead time?
Samples can start from a single piece. Lead time depends on size, form, coating and quantity, so we confirm a date with every quotation based on current coating capacity, rather than promising a fixed number that may not hold for your project.
08Can you recoat used electrodes and sign an NDA?
Yes. Where the titanium substrate is still sound, we can strip and recoat used anodes after inspection. We are also happy to sign your NDA before you send drawings, and your files are used only for your orders.

Have a question that is not listed? Ask our engineers directly and get a written answer.

Ask an Engineer
Specification Builder

Build Your Custom Electrode Specification and Get an Engineering Review

Four short steps turn what you know today into a specification our engineers can review. You receive feedback on missing data, a coating direction and a quotation broken down by sample, pilot and series quantities.

ARY engineers reviewing a customer electrode specification on a tablet
Engineering reply, not an auto-quoteA real engineer reads your data and replies with questions or a proposal.
Your drawings stay confidentialNDA available before upload; files used only for your project.
Start small1–10 piece samples to validate before any volume commitment.

What happens after you submit

  1. We review your data and list any gaps.
  2. You receive a coating direction and drawing notes.
  3. You get a quotation with sample and series prices.

Custom Electrode Request

Fields marked * are required. Unknown values can be left blank.

1 · Start & Company
2 · Operating Conditions
3 · Design Details
4 · Files & Quantity

Four quick steps, then an engineer reviews your specification.

Your specification is ready. Send it to our engineering team for review.

Your files and data are kept confidential.
Thank you, your request has been received.

An ARY engineer will review your specification and reply by email.