- Home
- Applications
Titanium Electrodes Matched to Your Electrochemical Application
MMO titanium anodes, platinum coated titanium electrodes, custom electrodes and electrolytic components, developed around your process, electrolyte, target reaction, electrical load, equipment geometry and validation plan.
What Should Your Electrochemical System Achieve?
Start from what the equipment must do, not from a coating name. Pick a goal to see the application page and the first data we review.
Treat or disinfect water
Water Treatment & Disinfection
We review the water or electrolyte, treatment objective, target reaction, electrical data and cell arrangement.
First data to prepare
- Water analysis and treatment objective
- Current, voltage and flow
- Cell drawing or arrangement
Generate sodium hypochlorite or active chlorine
Sodium Hypochlorite Generation
We review the brine, target available-chlorine output, current, voltage, flow and electrolyzer design.
First data to prepare
- Brine source and chloride concentration
- Target output and solution concentration
- Current, voltage, temperature and flow
Separate ions or manage scaling
Electrodialysis & Descaling
We review the feed-water analysis, membrane-stack or reactor role, electrode rinse, polarity mode and deposit conditions.
First data to prepare
- Feed-water analysis and target
- Electrode rinse and polarity mode
- Hardness, deposits and cleaning method
Plate or recover metals
Electroplating & Electrowinning
We review the target metal, electrolyte, anodic reaction, cathodic result, current distribution and cell geometry.
First data to prepare
- Target metal and electrolyte
- Anodic reaction and additives
- Current distribution and tank drawing
Protect metallic structures from corrosion
Cathodic Protection
We review the approved cathodic-protection design, protected structure, environment, current requirement, anode arrangement and electrical circuit.
First data to prepare
- Approved CP design basis
- Protected asset and environment
- Required current and anode arrangement
Produce hydrogen-rich water in compact devices
Hydrogen Water Systems
We review the device type, water, cell configuration, electrode roles, current, voltage, dimensions and validation plan.
First data to prepare
- Device type and cell configuration
- Water conditions and electrode roles
- Current, voltage and dimensions
Your goal is not listed, or your process combines several of them?
Describe My ProjectThe Application Name Is the Starting Point, Not the Electrode Specification
The same titanium form can serve very different electrochemical roles. A responsible recommendation starts with the process, then defines the coating, substrate, geometry, connections, validation and production controls.
Define the objective
What must the equipment generate, separate, treat, recover or protect?
Define the reactions
What is the electrolyte, and what should occur at the anode and cathode?
Define the electrical window
Current density, total current, voltage, temperature, polarity and duty cycle.
Define the interface
Dimensions, active area, spacing, flow, mounting, welding and connections.
Define validation
How fit, electrical behaviour and process result will be tested.
Define repeat supply
Drawing revision, inspection points, labels, packaging and change control.
Already have part of this data? Send it and we will tell you what is still missing.
Send What I HaveMatch the Titanium Electrode to the Water You Actually Run
Water-treatment electrodes are selected from the actual water or electrolyte, the treatment objective, the target reaction, electrical load, flow, geometry and validation method.
- Water or electrolyte analysis
- Treatment or disinfection objective
- Target reaction and coating direction
- Electrode and cell arrangement
- Test and acceptance method
Key data
- Water analysis
- Chloride
- pH
- Temperature
- Current density
- Flow
- Duty cycle
See how these inputs shape the coating and electrode direction.
Explore Water Treatment & DisinfectionDevelop the Electrode Around the Brine, Output and Electrolyzer
For sodium hypochlorite generators, electrode selection depends on the brine, target available-chlorine output, electrical window, temperature, flow, electrode spacing, cell interfaces and test conditions.
- Water and salt preparation
- Brine chemistry and concentration
- Titanium anode, cathode and cell geometry
- Current, voltage, temperature and flow
- Output validation, pilot and repeat supply
Key data
- Salt source
- Chloride
- Target output
- Total current
- Voltage
- Cell drawing
Building or upgrading a hypochlorite generator?
Explore Sodium Hypochlorite GenerationDefine the Process Path Before Defining the Electrode
Electrodialysis, electrodialysis reversal and electrochemical descaling use different ion-transport, polarity, rinse, deposit and maintenance logic. We separate the paths first.
Path A · Membrane stack
Electrodialysis or EDR
Stack-end electrodes work beside the membranes and the electrode rinse, sometimes with polarity reversal.
- Feed, diluate, concentrate and electrode rinse
- Fixed or reversing polarity
- Stack drawing and electrode chamber
Custom electrode evaluation
Path B · Electrochemical reactor
Electrochemical Softening or Descaling
The electrode controls where hardness deposits form and how the collection surface is cleaned.
- Hardness, alkalinity and deposit location
- Collection surface and cleaning method
- Reactor drawing and validation
Not sure which path your system follows?
Explore Electrodialysis & DescalingUse the Bath and Electrode Reactions to Define the Titanium Anode
Plating and metal-recovery projects need more than an anode size. The electrolyte, target metal, anodic reaction, cathodic result, current distribution, spacing and bath control all shape the anode.
- Electroplating, electrowinning or metal recovery
- Soluble, insoluble or auxiliary anode role
- Electrolyte, additives and impurities
- Current distribution, geometry and spacing
- Gas, bath control and validation
Key data
- Target metal
- Electrolyte
- Additives
- Current density
- Anode-cathode spacing
- Tank drawing
Switching to insoluble titanium anodes, or optimising an existing bath?
Explore Electroplating & ElectrowinningCustom MMO Titanium Anodes for Engineered ICCP Projects
We evaluate coated titanium anodes against the approved impressed-current design, environment, current requirement, anode arrangement, connection, installation and supply specification.
Rectifier
Output and power limits from the CP design.
Positive cable
Cable, joint and connection to the anode.
MMO titanium anode
Form, coated area and mounting.
Electrolyte
Soil, water, concrete or backfill.
Protected structure
Pipeline, tank, pile or marine steel.
Negative return
Return path and monitoring points.
ARY Titanium supports anode manufacturing and supply. System design, protection criteria, potential assessment and commissioning approval remain with the qualified cathodic-protection engineer.
Key data
- Protected asset
- Environment
- Resistivity
- Required current
- Rectifier limits
- Anode arrangement
Supplying anodes to an approved ICCP design?
Explore Cathodic Protection
Hydrogen Water SystemsCustom Titanium Electrodes for Hydrogen Water Cups and Machines
Compact devices need electrodes matched to the cell type, water, electrode roles, current, voltage, operating cycle, dimensions, contacts and device-level validation.
- Device type and user experience
- Direct electrolysis or membrane cell
- Anode, cathode and coating direction
- Compact geometry, contacts and sealing
- Sample testing and repeat production
Device types
- Cups and bottles
- Countertop machines
- Inline and under-sink
- Modules and prototypes
Building a hydrogen water device?
Explore Hydrogen Water SystemsSix Applications Side by Side
Compare the process objective, medium, electrode role and critical inputs before you open a full application page.
| Application | Process objective | Medium | Electrode role to confirm | Critical inputs |
|---|---|---|---|---|
| Water treatment | Treat, disinfect, remove or transform | Water or electrolyte | Application-matched anode and matching electrode | Water analysis, reaction, current, voltage, flow, cell |
| Sodium hypochlorite | Generate hypochlorite solution | Prepared brine | Chlorine-evolution anode and matching cathode | Chloride, output, current, voltage, temperature, flow, spacing |
| Electrodialysis & descaling | Separate ions or manage hardness deposits | Feed water, electrode rinse or reactor water | Stack-end electrode or descaling electrode component | Ions, rinse, polarity, flow, hardness, deposits, cleaning |
| Electroplating & electrowinning | Plate or recover metal | Metal-bearing plating or recovery electrolyte | Insoluble coated anode, auxiliary anode or counter-electrode | Target metal, bath, reactions, current distribution, geometry |
| Cathodic protection | Deliver protective current to a structure | Soil, water, concrete or backfill | Impressed-current anode in an engineered CP circuit | Structure, environment, resistivity, current, arrangement, connections |
| Hydrogen water | Generate hydrogen-rich water in a compact device | Device water and cell electrolyte | Device-specific anode, cathode or electrode pair | Device type, water, cell, current, voltage, dimensions, validation |
This matrix routes your inquiry. It does not replace a project-specific engineering review or define a universal coating.
Found your row? Send the critical inputs listed for it.
Send My Critical InputsRoute the Reaction Before You Discuss the Coating
MMO, ruthenium-iridium, iridium-tantalum and platinum coated titanium serve different requirements. The application narrows the discussion; your operating data decides what should be evaluated.
- Electrolyte composition and concentration
- Chlorine evolution, oxygen evolution or other reaction
- Cathodic process or protected structure
- Current density, voltage, temperature, duty cycle
- Titanium form, active area, flow and connections
Coating direction discussion
With our engineers, based on your data and test method.
No coating is universal. Output, efficiency, service life and process results depend on the complete system and operating data.
Want a coating direction for your reaction?
Send the Operating Data for a Coating DiscussionFrom Application Data to a Repeatable Titanium Electrode
Drawing-based OEM projects, custom forms, welding, connections, sample quantities, pilot validation and repeat production. The process starts with your application data, not a catalogue item.
Data intake
Project data, drawing or sample received.
Missing-info review
Open questions listed before quoting.
Definition
Coating, form, geometry and connection agreed.
Drawing approval
Specification confirmed in writing.
Sample & pilot
Validated in your own equipment.
Repeat production
Part identity, packaging and delivery.
You provide
- Operating conditions
- Target result
- Drawing or sample
- Test method
- Quantity
- Delivery requirements
We return
- Open questions
- Feasibility feedback
- Confirmed drawing
- Samples
- Inspection communication
- Repeat-order reference
Drawings, project names, bath or water data and custom designs are used only for the agreed quotation and production scope. NDA available on request.
Read how we run drawing-based OEM projects.
View Custom ServiceControl the Details That Connect the Approved Sample to Repeat Supply
The quality scope is confirmed for each project. Repeat supply stays linked to the approved drawing, dimensions, connections, inspection points, identification and packaging.
Incoming material
Titanium grade and form reviewed.
Surface preparation
Cleaning and roughening controlled.
Coating process
Process parameters kept consistent.
Dimensions & active area
Size, flatness and holes checked.
Welds & connections
Tabs, frames and supports inspected.
Visual & electrical
Surface checks and applicable tests.
Final verification
Drawing, part identity and quantity.
Protective packing
Pre-shipment review and packing.
Change record
Approved sample linked to each batch.
Inspection records and material information are provided where available and agreed for your project.
Qualifying a new electrode supplier? See how each checkpoint works.
View Quality ControlPrepare Better Project Data Before You Request a Quote
Understand the operating information, drawings and validation details that make a technical discussion useful.
Titanium Substrates and Electrode Forms
Plate, mesh, expanded mesh, rod, tube and welded assemblies serve different current, flow and gas-release needs.
Relevant to
- All six applications
MMO, Platinum and Other Coating Directions
Ru-Ir, Ir-Ta and platinum coatings are chosen by reaction and electrolyte, not by product name.
Relevant to
- Water treatment
- Sodium hypochlorite
- Electroplating
- Hydrogen water
Chlorine Evolution Versus Oxygen Evolution
Many early anode failures trace back to one wrong assumption about which reaction dominates in the cell.
Relevant to
- Sodium hypochlorite
- Electrowinning
- Cathodic protection
Current Density, Active Area, Voltage and Connections
The active area sizes the current density, and the terminal decides whether current enters without hot spots.
Relevant to
- All six applications
Information Required for Correct Selection
Process data, geometry data and commercial data: what to send so the first reply is accurate.
Relevant to
- All six applications
Installation, Cleaning, Handling and Premature Failure
Coating damage, deposits and connection problems are often prevented at installation and in routine cleaning.
Relevant to
- Electrodialysis & descaling
- Water treatment
- Electroplating
Have a question the resources do not answer?
Ask an Application QuestionTell Us What Your Equipment Needs to Achieve
Submit the process and equipment data you have. We review the application, list any missing information and reply with the next technical and commercial steps.
- An application-specific checklist appears when you pick one
- Drawings and water or bath data can follow by email
- NDA available for confidential designs
Application Project
Fields marked * are required.